<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-16 14-21-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 69 dBuV YLEX
Pilot RDS Phase Difference
7.3 kHz 2.2 kHz 60 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 63 kHz 19059 0,1731
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,1 dBr 1,60 dBr 4,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 14:21, 16.10.2024
RT
"SHRTY - Sirkus "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6903, 6205, 6201, 6207
FM Scope Max at: 63 kHz MIN: 10 kHz % above 76 kHz: 0,1731 Acquired: 2024/10/16 14.20.50 Total samples: 19059 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,6 dBr MIN: -0,1 dBr AVE: 1,60 dBr % above 12,2 dBr: 0,0 Last value: 4,1 dBr (2024/10/16 14.20.50) 14.06 14.08 14.10 14.12 14.14 14.16 14.18 14.20 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr]